Best viewed in
Microsoft Internet Explorer

SERVICES OFFERED:
Floors
Standard Service: Provide and install Bonder product. Check for potential leaks. Additional Service: Provide and install a Sealer.

TYPICAL PROJECT TIMETABLE
Radiant Floor
2,000 sq ft area
2 hour setup
1 hour pour
2 hour breakdown/cleanup
Ready to walk on the following morning

JOB REQUIREMENTS / SPECS
Floors to be broom clean. Major penetrations sealed against water leakage. Subfloors must be structurally sound with a minimum deflection rate of L/360. Floors will be loaded with 15 lbs/sq ft with installed 1-1/2" product. 10 to 15 gallons of water per minute required on site. Trash container for cleanup. Setup site [50' X 50'] within 50 feet of the building over unfinished grade with road access to site.

Radiant Heat pipe filled with fluid and pressure tested complete and installed per product specification.




PRODUCTS OFFERED:

Firm-Fill ® High Strength

Firm-Fill ® 4010

Firm Fill ® 2010

Gyp-Span® Radiant